Magnetic resonance image reconstruction from undersampled measurements using a patch-based nonlocal operator
Xiaobo Qua,*, Yingkun Houb, Fan Lamc, Di Guod, Jianhui Zhonge, Zhong Chena,*
a Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, China
b School of Information Science and Technology, Taishan University, Taian 271021, China
c Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
d School of Computer and Information Engineering, Xiamen University of Technology, Xiamen 361024, China
e Department of Imaging Sciences, University of Rochester, Box 648, Elmwood Avenue, Rochester, NY 14642-8648, USA
Xiaobo Qu's Email: quxiaobo <at> xmu.edu.cn or quxiaobo2009 <at> gmail.com.
Abstract:
Compressed sensing MRI (CS-MRI) has shown great potential in reducing data acquisition time in MRI. Sparsity or compressibility plays an important role to reduce the image reconstruction error. Conventional CS-MRI typically uses a pre-defined sparsifying transform such as wavelet or finite difference, which sometimes does not lead to a sufficient sparse representation for the image to be reconstructed. In this paper, we design a patch-based nonlocal operator (PANO) to sparsify magnetic resonance images by making use of the similarity of image patches. The definition of PANO results in sparse representation for similar patches and allows us to establish a general formulation to trade the sparsity of these patches with the data consistency. It also provides feasibility to incorporate prior information learnt from undersampled data or another contrast image, which leads to optimized sparse representation of images to be reconstructed. Simulation results on in vivo data demonstrate that the proposed method achieves lower reconstruction error and higher visual quality than conventional CS-MRI methods.
The proposed method assumes that a guide image is available to give a good estimate of nonlocal similarity for image patches. This nonlocal similarity information is integrated as prior information into the proposed patch-based nonlocal operator (PANO), which is utilized to establish a general reconstruction formulation. The essential component of the proposed method is the design of the PANO.
Fig. 1. Group image patches. (a) An image with 6 6 pixels; (b) four groups of patches; (c) the patch and group dimension.
Fig. 2. Illustration of the similar patches found via block matching and the sparsity results in. (a) A search region X with and the reference patch T with
; (b) Q = 16 similar patches found by the
norm distance measure with patch size L = 8; (c) 3D array stacked from the similar patches, and (d) curves for decay of pixel values, 2D and 3D wavelet coefficients.
Fig. 3. Comparison of different guide images. (a) variable density Cartesian sampling pattern with sampling rate 0.40; (b) locations of low-frequency k-space data; (c) the fully sampled MR image; (d) reconstructed image from only the low-frequency k-space data; (e) reconstructed image from zero-filled k-space data; (f) reconstructed image from SIDWT.
Fig. 4. Flowchart of the proposed PANO-based MRI reconstruction from undersampled data.
Fig. 5. Images reconstructed using proposed method with the different guide images (a) fully sampled image in Fig. 3(c), (b) low-resolution image in Fig. 3(d), (c) zero-filling image in Fig. 3(e), and (d) conventional CS-MRI reconstruction in Fig. 3(f). The RLNEs of (a)–(d) are 0.077, 0.087, 0.083, 0.081.
Conclusions:
A new MR image reconstruction method is presented. The proposed method exploits nonlocal similarity of image patches by establishing a patch-based nonlocal operator, PANO, which effectively produces sparse vectors by operating on grouped similar patches of the image. A reconstruction formulation is proposed to incorporate a sparsity constraint on PANO-produced coefficients, which can be considered as a generalization of previously proposed patch-based reconstruction methods. Simulation results based on fully sampled experimental data demonstrated consistent improvement in reconstruction accuracy of the proposed method over conventional CS-MRI reconstructions and several alternative CS-based reconstructions. We have also shown that the similarity information required by PANO can be iteratively learnt from a guide image reconstructed from undersampled k-space data and the proposed method is not sensitive to the initial guide image. In general, only learning the similarity twice is sufficiently enough to maximize the performance of the proposed method for the tested images. When the data are highly undesampled, learning the similarity from another contrast image with fully sampled data greatly improve the reconstruction.
References:
Adluru, G., DiBella, E.V.R., 2008. Reordering for improved constrained reconstruction from undersampled k-space data. Int. J. Biomed. Imaging. Article ID 341684.
Adluru, G., Tasdizen, T., Schabel, M.C., DiBella, E.V.R., 2010. Reconstruction of 3D dynamic contrast-enhanced magnetic resonance imaging using nonlocal means. J. Magn. Reson. Imaging 32, 1217–1227.
Akçakaya, M., Basha, T.A., Goddu, B., Goepfert, L.A., Kissinger, K.V., Tarokh, V., Manning, W.J., Nezafat, R., 2011. Low-dimensional-structure self-learning and thresholding: regularization beyond compressed sensing for MRI Reconstruction. Magn. Reson. Med., 756–767.
Baker, C.A., King, K., Liang, D., Ying, L., 2011. Translational-invariant dictionaries for compressed sensing in magnetic resonance imaging. In: Proceedings of 8th IEEE International Symposium on Biomedical Imaging(ISBI’11), pp. 1602–1605.
Bao, L., Robini, M., Liu, W., Zhu, Y., 2013. Structure-adaptive sparse denoising for diffusion-tensor MRI. Med. Image Anal. 17, 442–457.
Baraniuk, R., Choi, H., Neelamani, R., Ribeiro, V., Romberg, J., Guo, H., Fernandes, F., Hendricks, B., Gopinath, R., Lang, M., Odegard, J.E., Wei, D., 2009. Rice Wavelet Toolbox, <http://dsp.rice.edu/software/rice-wavelet-toolbox>.
Bilgic, B., Adalsteinsson, E., 2012. Joint Bayesian compressed sensing with prior estimate. In: Proceedings of 20th Scientific Meeting on International Society for, Magnetic Resonance in Medicine (ISMRM’12), pp. 75.
Bilgic, B., Goyal, V.K., Adalsteinsson, E., 2011. Multi-contrast reconstruction with Bayesian compressed sensing. Magn. Reson. Med. 66, 1601–1615.
Block, K.T., Uecker, M., Frahm, J., 2007. Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint. Magn. Reson. Med. 57, 1086–1098.
Buades, A., Coll, B., Morel, J.M., 2005. A review of image denoising algorithms, with a new one. Multiscale Model. Simulat. 4, 490–530.
Candes, E.J., Romberg, J., Tao, T., 2006. Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information. IEEE Trans. Inform. Theory 52, 489–509.
Chen, C., Huang, J., 2012. Compressive sensing MRI with wavelet tree sparsity. Adv. Neural Inform. Process. Syst. 25, 1124–1132.
Chen, Y.M., Ye, X.J., Huang, F., 2010. A novel method and fast algorithm for MR image reconstruction with significantly under-sampled data. Inverse Problem Imaging 4, 223–240.
Dabov, K., Foi, A., Katkovnik, V., Egiazarian, K., 2007. Image denoising by sparse 3-D transform-domain collaborative filtering. IEEE Trans. Image Process. 16, 2080–2095.
Dietrich, O., Raya, J.G., Reeder, S.B., Reiser, M.F., Schoenberg, S.O., 2007. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J. Magn. Reson. Imaging 26, 375–385.
Donoho, D.L., 2006. Compressed sensing. IEEE Trans. Inform. Theory 52, 1289–1306.
Egiazarian, K., Foi, A., Katkovnik, V., 2007. Compressed sensing image reconstruction via recursive spatially adaptive filtering. In: Proceedings of 14th IEEE International Conference on Image Processing (ICIP’07), pp. 549–552.
Elad, M., Matalon, B., Shtok, J., Zibulevsky, M., 2007. A wide-angle view at iterated shrinkage algorithms. In: Proceedings of Wavelets XII, August 26, 2007 – August 29, 2007. SPIE, San Diego, CA, USA.
Fang, S., Ying, K., Zhao, L., Cheng, J.P., 2010. Coherence regularization for SENSE reconstruction with a nonlocal operator (CORNOL). Magn. Reson. Med. 64, 1414–1426.
Gamper, U., Boesiger, P., Kozerke, S., 2008. Compressed sensing in dynamic MRI. Magn. Reson. Med. 59, 365–373.
Gho, S.M., Nam, Y., Zho, S.Y., Kim, E.Y., Kim, D.H., 2010. Three dimension double inversion recovery gray matter imaging using compressed sensing. Magn. Reson. Imaging 28, 1395–1402.
Haldar, J., Hernando, D., Liang, Z.P., 2011. Compressed-sensing MRI with random encoding. IEEE Trans. Med. Imaging 30, 893–903.
Henkelman, R.M., 1985. Measurement of signal intensities in the presence of noise in MR images. Med. Phys. 12, 232–233.
Hu, C.W., Qu, X.B., Guo, D., Bao, L.J., Chen, Z., 2011. Wavelet-based edge correlation incorporated iterative reconstruction for undersampled MRI. Magn. Reson. Imaging 29, 907–915.
Huang, J. Z., Chen, C., Axel, L., 2012. Fast multi-contrast MRI reconstruction. In: Proceedings of 15th International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI’12), pp. 281–288.
Huang, J.Z., Yang, F., 2012. Compressed magnetic resonance imaging based on wavelet sparsity and nonlocal total variation. In: Proceedings of 9th IEEE International Symposium on Biomedical, Imaging (ISBI’09), pp. 968–971.
Huang, J.Z., Zhang, S.T., Metaxas, D., 2011. Efficient MR image reconstruction for compressed MR Imaging. Med. Image Anal. 15, 670–679.
Jung, H., Sung, K., Nayak, K.S., Kim, E.Y., Ye, J.C., 2009. K-t FOCUSS: a general compressed sensing framework for high resolution dynamic MRI. Magn. Reson. Med. 61, 103–116.
Knoll, F., Bredies, K., Pock, T., Stollberger, R., 2011. Second order total generalized variation (TGV) for MRI. Magn. Reson. Med. 65, 480–491.
Liang, D., Wang, H., Chang, Y., Ying, L., 2011. Sensitivity encoding reconstruction with nonlocal total variation regularization. Magn. Reson. Med. 65, 1384–1392.
Lingala, S.G., Hu, Y., DiBella, E., Jacob, M., 2011. Accelerated dynamic MRI exploiting sparsity and low-rank structure: k–t SLR. IEEE Trans. Med. Imaging 30, 1042–1054.
Lustig, M., Donoho, D., Pauly, J.M., 2007. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn. Reson. Med. 58, 1182–1195.
Lustig, M., Pauly, J.M., 2010. SPIRiT: iterative self-consistent parallel imaging reconstruction from arbitrary k-space. Magn. Reson. Med. 64, 457–471.
Maggioni, M., Katkovnik, V., Egiazarian, K., Foi, A., 2013. Nonlocal transform-domain filter for volumetric data denoising and reconstruction. IEEE Trans. Image Process. 22, 119–133.
Majumdar, A., Ward, R.K., 2011. Joint reconstruction of multiecho MR images using correlated sparsity. Magn. Reson. Imaging 29, 899–906.
Manjón, J.V., Carbonell-Caballero, J., Lull, J.J., Garcia-Marti, G., Marti-Bonmati, L., Robles, M., 2008. MRI denoising using non-local means. Med. Image Anal. 12, 514–523.
Manjón, J.V., Coupé, P., Buades, A., Louis Collins, D.L., Robles, M., 2012. New methods for MRI denoising based on sparseness and self-similarity. Med. Image Anal. 16, 18–27.
Manjón, J.V., Coupé, P., Buades, A., Collins, D.L., Robles, M., 2010. MRI superresolution using self-similarity and image priors. Int. J. Biomed. Imaging. Article ID 425891.
Ning, B., Qu, X., Guo, D., Hu, C., Chen, Z., 2013. Magnetic resonance image reconstruction using trained geometric directions in 2D redundant wavelets domain and non-convex optimization. Magnetic Resonance Imaging 31 (9), 1611–1622.
Otazo, R., Kim, D., Axel, L., Sodickson, D.K., 2010. Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI. Magn. Reson. Med. 64, 767–776.
Qu, X.B., Cao, X., Guo, D., Hu, C.W., Chen, Z., 2010a. Combined sparsifying transforms for compressed sensing MRI. Electron. Lett. 46, 121–122.
Qu, X.B., Guo, D., Ning, B.D., Hou, Y.K., Lin, Y.L., Cai, S.H., Chen, Z., 2012. Undersampled MRI reconstruction with patch-based directional wavelets. Magn. Reson. Imaging 30, 964–977.
Qu, X.B., Hu, C.W., Guo, D., Bao, L.J., Chen, Z., 2011. Gaussian scale mixture-based joint reconstruction of multicomponent MR images from undersampled k-space measurements. In: Proceedings of 19th Scientific Meeting on International Society for, Magnetic Resonance in Medicine (ISMRM’11), pp. 2838.
Qu, X.B., Zhang, W.R., Guo, D., Cai, C.B., Cai, S.H., Chen, Z., 2010b. Iterative thresholding compressed sensing MRI based on contourlet transform. Inverse Probl. Sci. Eng. 18, 737–758.
Ravishankar, S., Bresler, Y., 2011. MR image reconstruction from highly undersampled k-space data by dictionary learning. IEEE Trans. Med. Imaging 30, 1028–1041.
Rousseau, F., 2010. A non-local approach for image super-resolution using intermodality priors. Med. Image Anal. 14, 594–605.
Seeger, M., Nickisch, H., Pohmann, R., Scholkopf, B., 2010. Optimization of k-space trajectories for compressed sensing by Bayesian experimental design. Magn. Reson. Med. 63, 116–126.
Shewchuk, J.R., 1994. An introduction to the Conjugate Gradient Method without the Agonizing Pain. Carnegie Mellon University, Pittsburgh, PA, USA.
Trzasko, J., Manduca, A., 2009. Highly undersampled magnetic resonance image reconstruction via homotopic l0-minimization. IEEE Trans. Med. Imaging 28, 106–121.
Trzasko, J.D., Haider, C.R., Borisch, E.A., Campeau, N.G., Glockner, J.F., Riederer, S.J., Manduca, A., 2011. Sparse-CAPR: highly accelerated 4D CE-MRA with parallel imaging and nonconvex compressive sensing. Magn. Reson. Med. 66, 1019–1032.
Vasanawala, S.S., Alley, M.T., Hargreaves, B.A., Barth, R.A., Pauly, J.M., Lustig, M., 2010. Improved pediatric MR imaging with compressed sensing. Radiology 256, 607–616.
Wang, Y.L., Yang, J.F., Yin, W.T., Zhang, Y., 2008. A new alternating minimization algorithm for total variation image reconstruction. SIAM J. Imaging Sci. 1, 248–272.
Wong, A., Mishra, A., Fieguth, P., Clausi, D., 2013. Sparse reconstruction of breast MRI using Homotopic L0 minimization in a regional sparsified domain. IEEE Trans. Biomed. Eng. 60, 743–752.
Wu, B., Millane, R.P., Watts, R., Bones, P.J., 2011. Prior estimate-based compressed sensing in parallel MRI. Magn. Reson. Med. 65, 83–95. Yang, J.F., Zhang, Y., Yin, W.T., 2009. A fast TVL1-L2 minimization algorithm for signal reconstruction from partial Fourier data. Rice University, <ftp://ftp.math.ucla.edu/pub/camreport/cam09-24.pdf>.
Yang, J.F., Zhang, Y., Yin, W.T., 2010. A fast alternating direction method for TV l1–l2 signal reconstruction from partial Fourier data. IEEE J. Sel. Topics Signal Process. 4, 288–297.
Ying, D., Jim, J., 2011. Compressive sensing MRI with laplacian sparsifying transform. In: Proceedings of 8th IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI’11), pp. 81–84.
Zhao, B., Haldar, J.P., Christodoulou, A.G., Liang, Z.P., 2012. Image reconstruction from highly undersampled (k, t)-space data with joint partial separability and sparsity constraints. IEEE Trans. Med. Imaging 31, 1809–1820.
Zhuo, Y., Bradley, S., Wu, X.L., Haldar, J., Hwu, W.M., Liang, Z.P., 2010. Sparse regularization in MRI iterative reconstruction using GPUs. In: Proceedings of 3rd International Conference on Biomedical Engineering and Informatics (BMEI’10), pp. 578–582.